Studi Perbandingan Efektivitas Desain Secara Pompa dan Kombinasi Terhadap Biaya dan Kontinuitas dalam Perencanaan Sistem Penyediaan Air Minum (SPAM) di Kec. Kebonsari Kab, Madiun

Prasasti, Andhyanerra Irsia (2026) Studi Perbandingan Efektivitas Desain Secara Pompa dan Kombinasi Terhadap Biaya dan Kontinuitas dalam Perencanaan Sistem Penyediaan Air Minum (SPAM) di Kec. Kebonsari Kab, Madiun. Undergraduate thesis, UPN Veteran Jawa Timur.

[img]
Preview
Text (Cover)
21034010116_cover.pdf

Download (1MB) | Preview
[img]
Preview
Text (Bab 1)
21034010116_bab1.pdf

Download (289kB) | Preview
[img] Text (Bab 2)
21034010116_bab2.pdf
Restricted to Repository staff only until 7 July 2029.

Download (430kB)
[img] Text (Bab 3)
21034010116_bab3.pdf
Restricted to Repository staff only until 7 July 2029.

Download (546kB)
[img] Text (Bab 4)
21034010116_bab4.pdf
Restricted to Repository staff only until 7 July 2029.

Download (1MB)
[img]
Preview
Text (Bab 5)
21034010116_bab5.pdf

Download (124kB) | Preview
[img]
Preview
Text (Daftar Pustaka)
21034010116_daftarpustaka.pdf

Download (194kB) | Preview
[img] Text (Lampiran)
21034010116_lampiran.pdf
Restricted to Repository staff only until 7 July 2029.

Download (11MB)

Abstract

This study aims to design a drinking water supply system (SPAM) in Kebonsari District, Madiun Regency, using two alternative systems, namely a pumping system and a combined system. The planning period considered in this study is 20 years. Furthermore, the selection of the best alternative was carried out using the Analytical Hierarchy Process (AHP) method to determine which system provides more continuous service. Based on the results, the required discharge for a 20-year service period, with a service coverage of 50% of the total population (equivalent to 7 villages within one district), is 109.32 L/s. Overall, the hydraulic profile calculations and simulations using EPANET 2.2 have shown results that comply with the design criteria. The simulation results indicate that the system meets the planning standards, where the residual pressure in the network remains above 10 m and the flow velocity ranges between 0.3–1 m/s. This velocity range is considered optimal as it prevents sedimentation and clogging in the pipeline while minimizing energy losses that could potentially damage the pipes. Of the two alternative systems planned using the AHP assessment method, the pump system is considered superior to the combined system.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDKEmail
Thesis advisorAmalia, AussieNIDN0024119201aussieamalia.tl@upnjatim.ac.id
Thesis advisorMurti, Restu Hikmah AyuNIDN0016049303restu.hikmah.tl@upnjatim.ac.id
Subjects: T Technology > TD Environmental technology. Sanitary engineering
Divisions: Faculty of Engineering > Departement of Environmental Engineering
Depositing User: Andhyanerra Irsia Prasasti
Date Deposited: 08 Jul 2026 06:28
Last Modified: 08 Jul 2026 06:28
URI: https://repository.upnjatim.ac.id/id/eprint/54770

Actions (login required)

View Item View Item