Kombinasi Media Filter Karbon Aktif Alami dengan Metode Slow Sand Filter (SSF) untuk Menurunkan BOD, COD, Kekeruhan, dan TSS Pada Air Telaga

Pratiwi, Safitri Wahyu (2024) Kombinasi Media Filter Karbon Aktif Alami dengan Metode Slow Sand Filter (SSF) untuk Menurunkan BOD, COD, Kekeruhan, dan TSS Pada Air Telaga. Undergraduate thesis, UPN Veteran Jawa Timur.

[img] Text (20034010060.-cover)
20034010060.-cover.pdf

Download (3MB)
[img] Text (20034010060.-bab1)
20034010060.-bab1.pdf

Download (129kB)
[img] Text (20034010060.-bab2)
20034010060.-bab2.pdf
Restricted to Repository staff only until 11 December 2027.

Download (396kB)
[img] Text (20034010060.-bab3)
20034010060.-bab3.pdf
Restricted to Repository staff only until 11 December 2027.

Download (306kB)
[img] Text (20034010060.-bab4)
20034010060.-bab4.pdf
Restricted to Repository staff only until 11 December 2027.

Download (355kB)
[img] Text (20034010060.-bab5)
20034010060.-bab5.pdf

Download (119kB)
[img] Text (20034010060.-daftarpustaka)
20034010060.-daftarpustaka.pdf

Download (152kB)
[img] Text (20034010060.-lampiran)
20034010060.-lampiran.pdf
Restricted to Repository staff only until 11 December 2027.

Download (5MB)

Abstract

Lake water contaminated with domestic wastewater is a serious concern because it can pollute the surrounding environment, such as in Telaga Rambit, Gresik. Turbid water quality indicates pollution so that a treatment process is needed before use. This study aims to analyze the effect of activator type and flow rate on the filtration process using the slow sand filter (SSF) method, with a combination of coconut shell charcoal and rice husk charcoal media. The flow rate variations used were 0.1 m³/h and 0.3 m³/h, with hydrochloric acid (HCl) and phosphoric acid (H₃PO₄) activators. The results showed that Reactor B, which used H₃PO₄ with a flow rate of 0.1 m³/hour, was the most effective variation in reducing contaminant levels, namely BOD by 1.9 mg/L, COD by 6.26 mg/L, and TSS by 12 mg/l with the 25th sampling time. H₃PO₄ activator is proven to increase the adsorption ability of activated carbon media, especially in capturing suspended particles. The low flow rate also provided better stability during the filtration process, allowing for more effective particle retention. At 25 minutes, the filtration media had not reached saturation point, indicating that filtration could still improve with longer contact times. Keywords: Activator, Activated Carbon, Flow Rate, Slow Sand Filter

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDKEmail
Thesis advisorAmalia, AussieNIDN0024119201aussieamalia.tl@upnjatim.ac.id
Subjects: T Technology > TD Environmental technology. Sanitary engineering
Divisions: Faculty of Engineering > Departement of Environmental Engineering
Depositing User: Safitri Wahyu Pratiwi
Date Deposited: 11 Dec 2024 10:00
Last Modified: 11 Dec 2024 10:00
URI: https://repository.upnjatim.ac.id/id/eprint/32826

Actions (login required)

View Item View Item