Modifikasi Perencanaan Struktur Gedung Tower 3 Institut Teknologi Sepuluh November Menggunakan Balok Prategang

Purihita, Regina (2026) Modifikasi Perencanaan Struktur Gedung Tower 3 Institut Teknologi Sepuluh November Menggunakan Balok Prategang. Undergraduate thesis, UPN Veteran Jawa Timur.

[img] Text (Cover)
22035010105.-cover.pdf

Download (1MB)
[img] Text (Bab I)
22035010105.-bab 1.pdf

Download (288kB)
[img] Text (Bab II)
22035010105.-bab 2.pdf
Restricted to Repository staff only until 21 July 2029.

Download (544kB)
[img] Text (Bab III)
22035010105.-bab 3.pdf
Restricted to Repository staff only until 21 July 2029.

Download (1MB)
[img] Text (Bab IV)
22035010105.-bab 4.pdf
Restricted to Repository staff only until 21 July 2029.

Download (2MB)
[img] Text (Bab V)
22035010105.-bab 5.pdf

Download (214kB)
[img] Text (Daftar Pustaka)
22035010105.-dafta pustaka.pdf

Download (189kB)
[img] Text (Lampiran)
22035010105.-lampiran.pdf
Restricted to Repository staff only

Download (17MB)

Abstract

Pre-tensioned concrete is an effective structural system to overcome span limitations in conventional reinforced concrete, especially in multi-story buildings that require column-free spaces and good deflection control. The Tower 3 building of the Sepuluh November Institute of Technology (ITS), which consists of 13 floors, underwent a change in function on the 12th and 13th floors to become an auditorium space with a span of 18.6 m, necessitating a long span without a central column. This research aims to modify the building's structural design by applying post-tensioned prestressed concrete beams and evaluating their structural performance against seismic loads. The results of this final project in the design of post-tensioned beams with a span of 18.6 m yielded dimensions of 70/100 cm, consisting of 1 tendon with 20 strands for the roof floor beam and the 13th-floor beam with the same dimensions consisting of 1 tendon with 25 strands. The evaluation of the relationship between the prestressed beam and other structural elements shows safe performance and meets the planning permission limits, as evidenced by the nominal shear capacity of the Beam-Column Connection (BCC) of 8,485,281.37 N > 5,298,527 N in the X and Y directions. Based on the prestressed beam planning results, the percentage of prestress loss is less than 20% for the post-tensioning method, which is 19.464% for the beam on the 13th floor and 18.641% for the beam on the roof floor. The performance level obtained was 0.003 in the X and Y directions, categorizing the structure as Immediate Occupancy (IO) with a ductility of 4.33 in the X direction and 4.77 in the Y direction, thus the building structure falls into the partial ductility category. Keywords: Prestressed Concrete, Post-Tension, Loss of Prestress, Performance Level

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDKEmail
Thesis advisorKartini, WahyuNIDN0720046303wahyu.ts@upnjatim.ac.id
Thesis advisorSumaidi, SumaidiNIDN0707097901sumaidi.ts@upnjatim.ac.id
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Faculty of Engineering > Departement of Civil Engineering
Depositing User: Unnamed user with email 22035010105@student.upnjatim.ac.id
Date Deposited: 21 Jul 2026 08:11
Last Modified: 21 Jul 2026 08:12
URI: https://repository.upnjatim.ac.id/id/eprint/57146

Actions (login required)

View Item View Item