Laporan Praktik Kerja Lapangan Evaluasi Efisiensi Kinerja Heat Exchanger-03 pada Unit Kilang Di Pusat Pengembangan Sumber Daya Manusia Minyak Dan Gas Bumi Cepu

Muliina, Alia Febrianti (2025) Laporan Praktik Kerja Lapangan Evaluasi Efisiensi Kinerja Heat Exchanger-03 pada Unit Kilang Di Pusat Pengembangan Sumber Daya Manusia Minyak Dan Gas Bumi Cepu. Project Report (Praktek Kerja Lapang dan Magang). UPN Veteran Jawa Timur. (Unpublished)

This is the latest version of this item.

[img] Text (COVER)
COVER.pdf

Download (451kB)
[img] Text (BAB I)
BAB I.pdf

Download (368kB)
[img] Text (BAB II)
BAB II.pdf

Download (262kB)
[img] Text (BAB III)
BAB III.pdf
Restricted to Repository staff only until 3 November 2028.

Download (340kB)
[img] Text (BAB IV)
BAB IV.pdf
Restricted to Repository staff only until 3 November 2028.

Download (307kB)
[img] Text (BAB V)
BAB V.pdf
Restricted to Repository staff only until 3 November 2028.

Download (175kB)
[img] Text (BAB VI-VIII)
BAB VI-IX.pdf
Restricted to Repository staff only until 3 November 2028.

Download (944kB)
[img] Text (BAB IX)
BAB X.pdf
Restricted to Repository staff only until 3 November 2028.

Download (174kB)
[img] Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA.pdf

Download (169kB)
[img] Text (LAMPIRAN)
LAMPIRAN.pdf

Download (821kB)

Abstract

This Field Work Practice (PKL) was conducted at the Human Resources Development Center for Oil and Gas (PPSDM Migas) Cepu from November 1 to 30, 2024, with the aim of learning the crude oil refining process and evaluating the performance of heat exchanger number 03 (HE-03) used for crude oil preheating. The evaluation was carried out by analyzing the inlet and outlet temperatures on the shell side (solar) and tube side (crude oil), and calculating the effectiveness and efficiency using the Log Mean Temperature Difference (LMTD) method. The results showed that HE-03 had an efficiency of 71.25%, indicating that the unit operates well but requires regular maintenance to maintain optimal performance, demonstrating that HE-03 plays an important role in supporting energy efficiency at the PPSDM Migas Cepu refinery unit.

Item Type: Monograph (Project Report (Praktek Kerja Lapang dan Magang))
Contributors:
ContributionContributorsNIDN/NIDKEmail
Thesis advisorSuprianti, Lilik2302100057liliksuprianti.tk@upnjatim.ac.id
Subjects: T Technology > TP Chemical technology > TP155 Chemical engineering
Divisions: Faculty of Engineering > Departement of Chemical Engineering
Depositing User: Alia Febrianti Muliina
Date Deposited: 04 Nov 2025 02:08
Last Modified: 04 Nov 2025 02:08
URI: https://repository.upnjatim.ac.id/id/eprint/46005

Available Versions of this Item

  • Laporan Praktik Kerja Lapangan Evaluasi Efisiensi Kinerja Heat Exchanger-03 pada Unit Kilang Di Pusat Pengembangan Sumber Daya Manusia Minyak Dan Gas Bumi Cepu. (deposited 04 Nov 2025 02:08) [Currently Displayed]

Actions (login required)

View Item View Item