PENURUNAN KADAR BOD, COD DAN TSS DALAM LIMBAH CAIR TAHU DENGAN METODE AERASI DAN OZONASI

FEBRIANTI, DWI AYU (2024) PENURUNAN KADAR BOD, COD DAN TSS DALAM LIMBAH CAIR TAHU DENGAN METODE AERASI DAN OZONASI. Undergraduate thesis, UPN Veteran Jawa Timur.

[img] Text (COVER)
20031010030-COVER.pdf

Download (1MB)
[img] Text (BAB I)
20031010030-BAB 1 (RISET).pdf

Download (155kB)
[img] Text (BAB II)
20031010030-BAB 2 (RISET).pdf
Restricted to Repository staff only until 22 November 2026.

Download (186kB)
[img] Text (BAB III)
20031010030-BAB 3 (RISET).pdf
Restricted to Repository staff only until 22 November 2026.

Download (791kB)
[img] Text (BAB IV)
20031010030-BAB 4 (RISET).pdf
Restricted to Repository staff only until 22 November 2026.

Download (1MB)
[img] Text (BAB V)
20031010030-BAB 5 (RISET).pdf

Download (141kB)
[img] Text (DAFTAR PUSTAKA)
20031010030-DAFTAR PUSTAKA.pdf

Download (182kB)
[img] Text (LAMPIRAN)
20031010030-LAMPIRAN (RISET).pdf
Restricted to Repository staff only until 22 November 2026.

Download (2MB)

Abstract

Tofu industrial wastewater is usually not optimally treated. It contains high levels of pollutants. Based on the analysis of tofu liquid waste in Candi, Sidoarjo has COD, BOD, and TSS levels of 7704, 4726, and 94 mg/L, respectively. Waste with high pollutants cannot be released directly into the environment and, therefore, requires treatment. Waste treatment methods that can reduce the pollutant content are aeration and ozonation. Tofu wastewater treatment is done by diluting the waste 10 times, then aeration for 6 hours with a flow rate of 6 L/min. The results of the aeration process will be adjusted pH by adding a solution of NaOH 1 M with pH variations of 6, 7, 8, 9, and 10, after which the ozonation process with an ozone flow rate of 400 mg/hour and contact time for 60; 80; 100; 120; 140 minutes. The results of testing the levels of BOD, COD, and TSS in tofu liquid waste that has been carried out the aeration and ozonation process showed the highest reduction in levels at pH = 10 with a contact time of 140 minutes, which resulted in COD, BOD, and TSS levels of 662, 241, and 36mg/L, respectively.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDKEmail
Thesis advisorSUPRIHATIN, SUPRIHATINNIDN0708056303UNSPECIFIED
Subjects: T Technology > TP Chemical technology
Divisions: Faculty of Engineering > Departement of Chemical Engineering
Depositing User: Dwi Ayu Febrianti
Date Deposited: 13 Dec 2024 07:06
Last Modified: 13 Dec 2024 07:06
URI: https://repository.upnjatim.ac.id/id/eprint/32121

Actions (login required)

View Item View Item