Ardiani, Fira (2025) Praktik Kerja Lapangan di Pusat Pengembangan Sumber Daya Manusia Minyak dan Gas Bumi (PPSDM MIGAS) Cepu. Project Report (Praktek Kerja Lapang dan Magang). UPN Veteran Jawa Timur, UPN Veteran Jawa Timur. (Unpublished)
|
Text (Cover)
21031010131.-cover.pdf Download (846kB) |
|
|
Text (Bab 1)
21031010131._bab1.pdf Download (781kB) |
|
|
Text (Bab 2)
21031010131._bab2.pdf Download (420kB) |
|
|
Text (Bab 3)
21031010131._bab3.pdf Restricted to Repository staff only until 4 December 2028. Download (990kB) |
|
|
Text (Bab 4)
21031010131.-bab4.pdf Restricted to Repository staff only until 4 December 2028. Download (664kB) |
|
|
Text (Bab 5)
21031010131.-bab5.pdf Restricted to Repository staff only until 4 December 2028. Download (382kB) |
|
|
Text (Bab 6-8)
21031010131.-bab6-8.pdf Restricted to Repository staff only Download (533kB) |
|
|
Text (Bab 9)
21031010131.-bab9.pdf Download (839kB) |
|
|
Text (Bab 10)
21031010131.-bab10.pdf Download (299kB) |
|
|
Text (Daftar Pustaka)
21931010131.-daftarpustaka.pdf Download (286kB) |
Abstract
PPSDM Migas Cepu is one of the crude oil processing facilities operated by Pertamina's upstream regional 4 subholding zone 11 Cepu field. Crude oil processing involves equipment and operating units, one of which is a heat exchanger. A heat exchanger is a device used to transfer heat from one fluid to another. HE-01 is one of five heat exchanger units owned by the PPSDM Migas refinery unit. HE-01 functions as a preheater for crude oil that is placed in the tube before entering the furnace. Heat transfer in HE-01 can occur due to the temperature difference between fluids. However, in actual conditions, the amount of heat released by diesel and the heat received by crude oil are not equal. Therefore, this study was conducted to analyze the performance of HE-01 and determine whether its condition is still optimal for operation. In this study, observations were made using a quantitative approach through heat transfer efficiency calculations. The results of the calculations in this study show that the HE-01 device has a heat transfer efficiency value of 76.054% with heat released by the hot fluid of 222,892.9 btu/hour, while the heat absorbed by the cold fluid is 169,519.29 btu/hour, with a dirt factor (rd) value of 0.006, and a pressure drop of 0.00095 psi. Based on these parameters, HE-01 is still quite suitable for use. However, the efficiency of the device's performance is not optimal.
| Item Type: | Monograph (Project Report (Praktek Kerja Lapang dan Magang)) | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Contributors: |
|
||||||||
| Subjects: | T Technology > TP Chemical technology > TP155 Chemical engineering | ||||||||
| Divisions: | Faculty of Engineering > Departement of Chemical Engineering | ||||||||
| Depositing User: | Fira Ardiani Fira Ardiani | ||||||||
| Date Deposited: | 05 Dec 2025 09:12 | ||||||||
| Last Modified: | 05 Dec 2025 09:12 | ||||||||
| URI: | https://repository.upnjatim.ac.id/id/eprint/47925 |
Actions (login required)
![]() |
View Item |