ANALISIS PENGARUH EFEKTIFITAS PENEMPATAN SHEARWALL PADA GEDUNG HOTEL SHAFIRA

HARLIKA, MOHAMMAD SYAHRIL (2024) ANALISIS PENGARUH EFEKTIFITAS PENEMPATAN SHEARWALL PADA GEDUNG HOTEL SHAFIRA. Undergraduate thesis, UPN VETERAN JAWA TIMUR.

[img] Text (COVER)
17035010027-COVER.pdf

Download (3MB)
[img] Text (BAB I)
17035010027-BAB I.pdf

Download (608kB)
[img] Text (BAB II)
17035010027-BAB II.pdf
Restricted to Repository staff only until 30 July 2026.

Download (2MB) | Request a copy
[img] Text (BAB III)
17035010027-BAB III.pdf
Restricted to Repository staff only until 30 July 2026.

Download (3MB) | Request a copy
[img] Text (BAB IV)
17035010027-BAB IV.pdf
Restricted to Repository staff only until 30 July 2026.

Download (10MB) | Request a copy
[img] Text (BAB V)
17035010027-BAB V.pdf

Download (308kB)
[img] Text (DAFTAR PUSTAKA)
17035010027-DAFTAR PUSTAKA.pdf

Download (381kB)
[img] Text (LAMPIRAN)
17035010027-LAMPIRAN.pdf
Restricted to Repository staff only

Download (17MB) | Request a copy

Abstract

Hotel Shafira is a flat-shaped 10-story building with a width of 12 meters and a length of 72 meters. Such a building shape is very susceptible to horizontal irregularities. Horizontal irregularities in buildings greatly reduce building efficiency. The irregularities that occur in this building are caused by the relatively uneven mass of the building. This can be seen from the differences in the span of the building portal. Portals with short spans are collected at the back while portals with long spans are collected at the front of the building, leaving large cavities. This is proven by the analysis of the ETABS program which shows that the eccentricity of the center of strength and center of mass in the direction of the strong axis is 5 meters. In this research, the uneven load distribution was overcome by re-placing the shearwall using trial and error until a smaller eccentricity was obtained. After the shearwall was added and rearranged, the pushover analysis results showed a base shear force of 37.78 kN and a displacement of 157.74 mm. This value is still much smaller than the capacity of the building which can withstand basic shear forces of up to 98.10 kN and displacements of up to 400 mm so that the building can be categorized at the Immediate Occupancy performance level. The building's eccentricity was also reduced from the original 5 meters to 1.3 meters. Reducing eccentricity can reduce internal forces so that the need for reinforcement is reduced by up to 13.9%.

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDKEmail
Thesis advisorKARTINI, WAHYUNIDN0720046303wahyu.ts@upnjatim.ac.id
Thesis advisorSUMAIDI, SUMAIDINIDN0707097901sumaidi.ts@upnjatim.ac.is
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Faculty of Engineering > Departement of Civil Engineering
Depositing User: MOHAMMAD SYAHRIL HARLIKA
Date Deposited: 30 Jul 2024 06:20
Last Modified: 30 Jul 2024 06:20
URI: https://repository.upnjatim.ac.id/id/eprint/28006

Actions (login required)

View Item View Item