Hidrodinamika Pada Airlift Reactor (ALR) Berbasis Computational Fluid Dynamics (CFD) Untuk Pengolahan Air Tanah Dengan Kandungan Fe dan Mn

Azzahra, Brigitta Ardiana Diva (2026) Hidrodinamika Pada Airlift Reactor (ALR) Berbasis Computational Fluid Dynamics (CFD) Untuk Pengolahan Air Tanah Dengan Kandungan Fe dan Mn. Undergraduate thesis, UPN Veteran Jawa Timur.

[img] Text (Cover)
22034010070-cover.pdf

Download (5MB)
[img] Text (Bab 1)
22034010070-bab1.pdf

Download (195kB)
[img] Text (Bab 2)
22034010070-bab2.pdf
Restricted to Repository staff only until 1 September 2029.

Download (480kB)
[img] Text (Bab 3)
22034010070-bab3.pdf
Restricted to Repository staff only until 1 September 2029.

Download (1MB)
[img] Text (Bab 4)
22034010070-bab4.pdf
Restricted to Repository staff only until 1 September 2029.

Download (1MB)
[img] Text (Bab 5)
22034010070-bab5.pdf

Download (187kB)
[img] Text (Daftar Pustaka)
22034010070-daftarpustaka.pdf

Download (206kB)
[img] Text (Lampiran)
22034010070-lampiran.pdf
Restricted to Repository staff only until 1 September 2029.

Download (10MB)

Abstract

Groundwater in Kebomas Sub-district, Gresik Regency, is affected by high concentrations of iron (Fe) and manganese (Mn), as well as low levels of dissolved oxygen (DO). These conditions highlight the need for treatment to improve groundwater quality. This study aims to analyse the effect of variations in draft tube density on hydrodynamic characteristics, oxygen mass transfer, and the removal of Fe and Mn using a continuously operated laboratory-scale airlift reactor (ALR). The study was conducted through experiments and Computational Fluid Dynamics (CFD) modelling, with draft tube densities of 0 mm, 3 mm and 5 mm. The water flow rate was 1 L/minute, the air flow rate was 7.5 L/minute, the diffuser diameter was 8 cm, and the process duration was 30 minutes. The results of the study showed that the initial groundwater had an Fe concentration of 0.36 mg/L, a Mn concentration of 0.61 mg/L, and a DO concentration of 3.4 mg/L. The 5-mm draft tube provided the best performance, with a final Fe concentration of 0.0124 mg/L and a removal efficiency of 96.56%, a final Mn concentration of 0.0850 mg/L and a removal efficiency of 86.07%, and a DO value of 6.8 mg/L. The volumetric oxygen mass transfer coefficient (kLa) also increased from 0.0406 min⁻¹ at a 0 mm variation to 0.0486 min⁻¹ at a 5 mm variation. Thus, a 5 mm variation in draft tube density represents the most optimal condition for enhancing oxygen transfer and removing Fe and Mn in the ALR system. Keywords : Groundwater, Airlift Reactor, Iron, Manganese, Draft Tube, Oxygen Transfer

Item Type: Thesis (Undergraduate)
Contributors:
ContributionContributorsNIDN/NIDKEmail
UNSPECIFIEDRachmanto, Tuhu AgungNIDN0001056209tuhu.tl@upnjatim.ac.id
Subjects: T Technology > TD Environmental technology. Sanitary engineering
Divisions: Faculty of Engineering > Departement of Environmental Engineering
Depositing User: Brigitta Ardiana Diva Azzahra
Date Deposited: 01 Sep 2026 04:27
Last Modified: 01 Sep 2026 05:52
URI: https://repository.upnjatim.ac.id/id/eprint/59609

Actions (login required)