LAPORAN PRAKTIK KERJA LAPANGAN DI PT. PETRO JORDAN ABADI, GRESIK, JAWA TIMUR

Agustina, Nurul Safira Maulida (2026) LAPORAN PRAKTIK KERJA LAPANGAN DI PT. PETRO JORDAN ABADI, GRESIK, JAWA TIMUR. Project Report (Praktek Kerja Lapang dan Magang). FTS UPN VETERAN JATIM.

[img] Text (Cover)
22031010109-cover.pdf

Download (388kB)
[img] Text (Bab 1)
22031010109-bab 1.pdf

Download (215kB)
[img] Text (Bab 2)
22031010109-bab 2.pdf
Restricted to Repository staff only until 27 August 2029.

Download (431kB)
[img] Text (Bab 3)
22031010109-bab 3.pdf
Restricted to Repository staff only until 27 August 2029.

Download (220kB)
[img] Text (Bab 4)
22031010109-bab 4.pdf
Restricted to Repository staff only until 27 August 2029.

Download (888kB)
[img] Text (Bab 5)
22031010109-bab 5.pdf
Restricted to Repository staff only until 27 August 2029.

Download (217kB)
[img] Text (Bab 6-9)
22031010109-bab 6-9.pdf
Restricted to Repository staff only until 27 August 2029.

Download (0B)
[img] Text (Bab 10)
22031010109-bab 10.pdf

Download (208kB)
[img] Text (Daftar Pustaka)
22031010109-daftar pustaka.pdf

Download (182kB)
[img] Text (Appendix)
22031010109-appendix.pdf
Restricted to Repository staff only until 27 August 2029.

Download (154kB)

Abstract

PT Petro Jordan Abadi is a chemical manufacturing company whose main product is phosphoric acid, with sulfuric acid, fluosilicic acid, and purified gypsum as by-products. The company consists of three main plants, namely the Sulphuric Acid Plant, Phosphoric Acid Plant, and Purified Gypsum Plant. Its utility systems include Water Treatment (WT), steam boilers, electricity generation through a Steam Turbine Generator (STG), compressed air, and instrument air, while wastewater management is carried out in the Wastewater Treatment Plant (WWT). Based on the performance evaluation of the Single Effect Evaporator (D-2501), the actual operating efficiency was found to be higher than that under the initial design conditions. Under the design conditions, the steam economy was 0.75, with an operating efficiency of approximately 75.49%, indicating an energy loss of approximately 24–26%. In contrast, under actual operating conditions, the steam economy increased to 0.98, with an operating efficiency of 98.22%, resulting in an energy loss of only approximately 1.78%. This increase in efficiency indicates that the evaporator performs more effectively under actual operating conditions compared with its initial design conditions.

Item Type: Monograph (Project Report (Praktek Kerja Lapang dan Magang))
Contributors:
ContributionContributorsNIDN/NIDKEmail
UNSPECIFIEDSari, Ni KetutNIP19650731 199203 2 001UNSPECIFIED
Subjects: T Technology > TP Chemical technology > TP155 Chemical engineering
Divisions: Faculty of Engineering > Departement of Chemical Engineering
Depositing User: Nurul Safira Maulida Agustina
Date Deposited: 01 Sep 2026 04:18
Last Modified: 01 Sep 2026 04:18
URI: https://repository.upnjatim.ac.id/id/eprint/59100

Actions (login required)