Wibowo, Bagus Tri (2026) KOMBINASI ADSORPSI DAN ELEKTROKOAGULASI RANGKAIAN BIPOLAR UNTUK MENGOLAH LIMBAH LAUNDRY DENGAN ADSORBEN TANAH LIAT TERAKTIVASI. Undergraduate thesis, Universitas Pembangunan Nasional “Veteran” Jawa Timur.
|
Text (Cover)
19034010057_Cover.pdf Download (5MB) | Preview |
|
|
Text (BAB I)
19034010057_BAB I.pdf Download (236kB) | Preview |
|
|
Text (BAB II)
19034010057_BAB II.pdf Restricted to Repository staff only until 7 July 2029. Download (531kB) |
||
|
Text (BAB III)
19034010057_BAB III.pdf Restricted to Repository staff only until 7 July 2029. Download (374kB) |
||
|
Text (BAB IV)
19034010057_BAB IV.pdf Restricted to Repository staff only until 7 July 2029. Download (1MB) |
||
|
Text (BAB V)
19034010057_BAB V.pdf Restricted to Repository staff only until 7 July 2029. Download (220kB) |
||
|
Text (Daftar Pustaka)
19034010057_Daftar Pustaka.pdf Download (214kB) | Preview |
|
|
Text (Lampiran)
19034010057_Lampiran.pdf Restricted to Repository staff only until 7 July 2029. Download (5MB) |
Abstract
Laundry wastewater contains high concentrations of surfactants, phosphates, and chemical oxygen demand (COD), which are difficult to remove using conventional treatment methods. This study aims to evaluate the effectiveness of a combined adsorption pre-treatment and bipolar electrocoagulation process for reducing pollutant loads in laundry wastewater. The electrocoagulation process was conducted under varying operating conditions, including treatment time, number of electrode plates, and applied voltage, to determine the optimal configuration. The pre-treatment stage employed clay-based adsorbents with variations in clay type, thermal activation temperature, and chemical activation. Key parameters analyzed included surfactants, phosphates, COD, and total suspended solids (TSS). The results indicated that the optimal condition was achieved using kaolin activated thermally at 500°C and chemically with 3 N HCl under slightly acidic conditions, followed by electrocoagulation using five electrode plates at an applied voltage of 25 V. Under these conditions, surfactant removal efficiency reached 98.89%, significantly higher than the 83.94% achieved without pre-treatment. These findings demonstrate that the integration of adsorption and bipolar electrocoagulation is an effective approach for enhancing the treatment performance of laundry wastewater. Keywords: Laundry wastewater, bipolar electrocoagulation, adsorption, kaolin, bentonite, surfactants, phosphate.
| Item Type: | Thesis (Undergraduate) | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Contributors: |
|
||||||||
| Subjects: | T Technology > TD Environmental technology. Sanitary engineering | ||||||||
| Divisions: | Faculty of Engineering > Departement of Environmental Engineering | ||||||||
| Depositing User: | Bagus Tri Wibowo | ||||||||
| Date Deposited: | 07 Jul 2026 02:26 | ||||||||
| Last Modified: | 07 Jul 2026 02:39 | ||||||||
| URI: | https://repository.upnjatim.ac.id/id/eprint/54726 |
Actions (login required)
![]() |
View Item |