Herazi, Yesi Nabila Zahro (2024) Penurunan Kandungan Logam Cu dan Cr Pada Limbah Cair Industri Elektroplating Menggunakan Metode Ion Exchange. Undergraduate thesis, UPN "VETERAN" JAWA TIMUR.
|
Text (COVER)
21031010163 - COVER.pdf Download (3MB) |
|
|
Text (BAB I)
21031010163 - BAB I.pdf Download (100kB) |
|
|
Text (BAB II)
21031010163 - BAB II.pdf Restricted to Repository staff only until 27 November 2027. Download (305kB) |
|
|
Text (BAB III)
21031010163 - BAB III.pdf Restricted to Repository staff only until 27 November 2027. Download (232kB) |
|
|
Text (BAB IV)
21031010163 - BAB IV.pdf Restricted to Repository staff only until 27 November 2027. Download (214kB) |
|
|
Text (BAB V)
21031010163 - BAB V.pdf Restricted to Registered users only until 27 November 2027. Download (92kB) |
|
|
Text (DAFTAR PUSTAKA)
21031010163 - DAFTAR PUSTAKA.pdf Restricted to Registered users only until 27 November 2027. Download (158kB) |
|
|
Text (LAMPIRAN)
21031010163 - LAMPIRAN.pdf Restricted to Repository staff only Download (391kB) |
Abstract
Electroplating industrial waste contains toxic chemicals that pose risks to health and environment, especially if they enter household wastewater systems. Therefore, treatment is necessary to reduce heavy metal content using the ion exchange method. This study utilized Amberlite IR 120Na resin as the ion exchange medium in electroplating waste. This study aims to reduce metal content in electroplating industrial wastewater using the ion exchange method by evaluating the effects of resin height and flow rate. The process was conducted with variations in flow rate (100 ml/min, 200 ml/min, 300 ml/min, 400 ml/min, 500 ml/min) and resin height (3 cm, 6 cm, 9 cm, 12 cm, 15 cm). The waste was passed through the ion exchange column, and the remaining Cu and Cr metal concentrations were measured. The results indicated that the optimal conditions occurred at a flow rate of 100 ml/min and a resin height of 15 cm, achieving a reduction of Cu metal by 90.16% and Cr metal by 83.36%. The Cu concentration after the process met quality standards under all conditions, while the Cr concentration met quality standards at resin heights of 12 cm and 15 cm. The ion exchange method proved effective in reducing heavy metal pollution.
| Item Type: | Thesis (Undergraduate) | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Contributors: |
|
||||||||
| Subjects: | G Geography. Anthropology. Recreation > GE Environmental Sciences T Technology > TP Chemical technology > TP155 Chemical engineering |
||||||||
| Divisions: | Faculty of Engineering > Departement of Chemical Engineering | ||||||||
| Depositing User: | YESI NABILA ZAHRO HERAZI | ||||||||
| Date Deposited: | 03 Dec 2025 08:19 | ||||||||
| Last Modified: | 03 Dec 2025 08:45 | ||||||||
| URI: | https://repository.upnjatim.ac.id/id/eprint/47074 |