JASA KONSULTANSI ENJINIRING PROYEK INFRASTRUKTUR GAS UNTUK SIMULASI LIQUEFIED NATURAL GAS (LNG) FLOATING STORAGE AND REGASIFICATION UNIT (FSRU) BIDANG PEMBANGKIT MENGGUNAKAN UNISIM

Yustisi, Kevin Christian (2023) JASA KONSULTANSI ENJINIRING PROYEK INFRASTRUKTUR GAS UNTUK SIMULASI LIQUEFIED NATURAL GAS (LNG) FLOATING STORAGE AND REGASIFICATION UNIT (FSRU) BIDANG PEMBANGKIT MENGGUNAKAN UNISIM. Project Report (Praktek Kerja Lapang). UPN Veteran Jawa Timur. (Unpublished)

[img]
Preview
Text (Cover)
COVER.pdf

Download (833kB) | Preview
[img]
Preview
Text (Bab 1)
BAB 1.pdf

Download (652kB) | Preview
[img]
Preview
Text (Bab 2)
BAB 2.pdf

Download (1MB) | Preview
[img] Text (Bab 3)
BAB 3.pdf
Restricted to Registered users only until 22 September 2026.

Download (340kB)
[img] Text (Bab 4)
BAB 4.pdf
Restricted to Registered users only until 22 September 2026.

Download (149kB)
[img] Text (Bab 5)
BAB 5.pdf
Restricted to Registered users only until 22 September 2026.

Download (429kB)
[img] Text (Bab 6-8)
Bab 6-8.pdf
Restricted to Registered users only until 22 September 2026.

Download (1MB)
[img]
Preview
Text (Bab 9)
BAB 9.pdf

Download (286kB) | Preview
[img]
Preview
Text (Daftar Pustaka)
DAFTAR PUSTAKA.pdf

Download (211kB) | Preview
[img] Text (Lampiran)
LAMPIRAN.pdf
Restricted to Registered users only until 22 September 2026.

Download (315kB)

Abstract

A simulation was conducted for a Floating Storage and Regasification Unit (FSRU) using an Integrated Flow Diagram (IFV). The simulation resulted in the following pump capacities: Pump P-101 with a capacity of 1087 m3/h, Pump P-102 with a capacity of 6477 m3/h (both pumps have an efficiency of 75%). The simulation also determined the seawater requirement for cooling glycol water, which is 7125 tonnes/hr, and this requires 12369.4 tonnes/hr of seawater. The simulated natural gas to be distributed is 411.3 MMSCFD. The pipeline used for the CCPP in Gresik is 52600 m long with an inside diameter of 26 inches, and the pipeline for CCPP in Grati is 52000 m long with an inside diameter of 26 inches. Both pipelines have Actual Vapour Velocity (ss) values below the API 14E limit.

Item Type: Monograph (Project Report (Praktek Kerja Lapang))
Contributors:
ContributionContributorsNIDN/NIDKEmail
UNSPECIFIEDRamadhan Yogaswara, RachmadNIDN0022048903UNSPECIFIED
Subjects: T Technology > TP Chemical technology > TP155 Chemical engineering
Divisions: Faculty of Engineering > Departement of Chemical Engineering
Depositing User: Mr Kevin Yustisi
Date Deposited: 22 Sep 2023 07:25
Last Modified: 22 Sep 2023 07:25
URI: http://repository.upnjatim.ac.id/id/eprint/18070