Aimia, Tasya Ambar (2023) Penyisihan COD, TSS, dan TN pada Lindi TPA Klotok Menggunakan Anoxic-Oxic Moving Bed Biofilm Reactor (MBBR). Undergraduate thesis, UPN Veteran Jawa Timur.
|
Text (Cover)
19034010032 - Cover.pdf Download (2MB) | Preview |
|
|
Text (Bab 1)
19034010032 - Bab 1.pdf Download (14kB) | Preview |
|
Text (Bab 2)
19034010032 - Bab 2.pdf Restricted to Repository staff only until 12 September 2025. Download (358kB) |
||
Text (Bab 3)
19034010032 - Bab 3.pdf Restricted to Repository staff only until 12 September 2025. Download (351kB) |
||
Text (Bab 4)
19034010032 - Bab 4.pdf Restricted to Repository staff only until 12 September 2025. Download (454kB) |
||
|
Text (Bab 5)
19034010032 - Bab 5.pdf Download (68kB) | Preview |
|
|
Text (Daftar Pustaka)
19034010032 - Daftar Pustaka.pdf Download (152kB) | Preview |
|
Text (Lampiran)
19034010032 - Lampiran.pdf Restricted to Repository staff only until 12 September 2025. Download (6MB) |
Abstract
Leachate is a liquid containing extracted, dissolved, and suspended materials from waste in a landfill. Leachate from Klotok landfill contains pollutant loads that do not meet the water quality standards, necessitating treatment. In this study, parameters considered were COD, TSS, and TN. Anoxic-Oxic Moving Bed Biofilm Reactor (MBBR) was chosen due to its compact footprint, low sludge production, ability to handle high COD loads, and not requiring periodic backwash. Variations including media type, media volume, and Hydraulic Retention Time (HRT) were applied to reduce pollutant parameter concentrations. The experiment was conducted in batch-continuous mode. The derived parameter concentrations yielded promising results using a biocube/sponge media in the reactor, constituting 50% of the leachate volume, with an HRT of 45 hours. Upon continuous operation under the best variations for parameter reduction, COD, TSS, and TN values were achieved as 160 mg⁄L, 132 mg⁄L, and 21.70 mg⁄L, respectively. Meanwhile, the average removal percentages for COD, TSS, and TN were 89.63%, 49.41%, and 89.69% respectively. Additionally, microorganism identification was performed in the anoxic-oxic moving bed biofilm reactor, revealing the presence of microorganisms such as coliforms, Bacillus sp., and Pseudomonas sp. Keywords: Anoxic-Oxic MBBR, Kaldnes K1 and Biocube, Leachate
Item Type: | Thesis (Undergraduate) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Contributors: |
|
||||||||
Subjects: | T Technology > TD Environmental technology. Sanitary engineering | ||||||||
Divisions: | Faculty of Engineering > Departement of Environmental Engineering | ||||||||
Depositing User: | Tasya Ambar Aimia | ||||||||
Date Deposited: | 13 Sep 2023 07:29 | ||||||||
Last Modified: | 13 Sep 2023 07:29 | ||||||||
URI: | http://repository.upnjatim.ac.id/id/eprint/17314 |
Actions (login required)
View Item |