WARDHANI, PUTRI AYU (2023) ANALISIS KUALITAS AIR KALI BUDURAN MENGGUNAKAN QUAL2KW SEBAGAI BAHAN BAKU IPAM SIWALANPANJI. Undergraduate thesis, UPN VETERAN JAWA TIMUR.
|
Text (COVER)
COVER.pdf Download (2MB) | Preview |
|
|
Text (BAB 1)
BAB 1.pdf Download (489kB) | Preview |
|
Text (BAB 2)
BAB 2.pdf Restricted to Registered users only until 19 January 2025. Download (694kB) |
||
Text (BAB 3)
BAB 3.pdf Restricted to Registered users only until 19 January 2025. Download (2MB) |
||
Text (BAB 4)
BAB 4.pdf Restricted to Registered users only until 19 January 2025. Download (1MB) |
||
|
Text (BAB 5)
BAB 5.pdf Download (347kB) | Preview |
|
|
Text
DAFTAR PUSTAKA.pdf Download (350kB) | Preview |
|
Text (LAMPIRAN)
LAMPIRAN.pdf Restricted to Registered users only until 20 January 2025. Download (1MB) |
Abstract
Kali Buduran, Sidoarjo Regency is one of the rivers in Sidoarjo City which has various functions. The main function of the Buduran River at this time is as a supply of raw material water for one of the branches of PDAM Delta Tirta Sidoarjo, namely the Water Treatment Plant branch in Siwalanpanji. For this reason, efforts are needed to maintain and monitor river quality using the Qual2Kw method. The QUAL2Kw method begins with the determination of 3 segments. Furthermore, analysis of hydraulic data, water quality, and pollutant sources was carried out, determining the scenario used, running the QUAL2Kw program and calculating the carrying capacity of the pollution load. River water quality parameters used include: temperature, pH, BOD, COD, TSS, Phosphate, and Nitrate. Application of the QUAL2Kw method in evaluating Buduran River by simulating 3 scenarios according to existing conditions, initial conditions according to quality standards, and trial & error with maximum pollutant load. The capacity value is determined based on the calculation of the difference in pollutant load in scenario 3 and scenario 2 . The result is that Buduran River is classified as a polluted river, the capacity of the pollutant load which is negative (-) indicates that management needs to be done to reduce the pollutant load. Keywords : Pollution load, capacity, water quality, QUAL2Kw modeling.
Item Type: | Thesis (Undergraduate) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Contributors: |
|
||||||||
Subjects: | T Technology > TD Environmental technology. Sanitary engineering | ||||||||
Divisions: | Faculty of Engineering > Departement of Environmental Engineering | ||||||||
Depositing User: | PUTRI AYU WARDHANI | ||||||||
Date Deposited: | 19 Jan 2023 08:52 | ||||||||
Last Modified: | 19 Jan 2023 08:52 | ||||||||
URI: | http://repository.upnjatim.ac.id/id/eprint/11227 |
Actions (login required)
View Item |